DC Wall Mount
Universally applicable
Adapted to most electric vehicles
Various communication
With Ethernet, 3G/4G, WIFI
Safety Protection
Over voltage, Under voltage. Over current. Short circuit. Ground fault and leakage protection
High inter-connectivity
Fully supports the Open Charge Point Protocol, compatible with all platforms developed based on OCPP protocol
Friendly interface
LCD touch screen. RFID reader
Efficient charging
The power module with high efficiency 95%
Multi-standard charging port combination
CCS2, CHAdeMO, GB/T, CCS1 can be combined and customized
High voltage output
Any car-wide voltage ranges from 200v-1000v
Intelligent operation
Not only can be operated on Teison OCPP platform, but also compatible with various OCPP platform connections
Optional appearance
Backstage monitoring
Real-time monitoring of the station status
Load balancing
More effective connection to the load system
| Specification | ||||
|---|---|---|---|---|
Model | H-EDW20-001 | H-EDW30-001 | H-EDW40-001 | |
| Electrical Properties | ||||
| AC Input | Input Rating | AC380V(+15%) 3ph | AC380V(+15%)3ph | AC380V(+15%)3ph |
| AC Input Connection | 3P+N+PE | 3P+N+PE | 3P+N+PE | |
| Rate Input Current | 3Ø33A | 3Ø50A | 3Ø66A | |
| Frequency | 50/60Hz | 50/60Hz | 50/60Hz | |
| Power Factor | ≥0.99 | ≥0.99 | ≥0.99 | |
| Efficiency | ≥95% | ≥95% | ≥95% | |
| DC Output | Output Voltage Range | 200V-1000V | 200V-1000V | 200V-1000V |
| MAx.Output Current | 66A(system) | 80A(system) | 133A(system) | |
| MAx.Output Power | DC20kW | DC30kW | DC40kW | |
| Voltage Accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | |
| Current Accuracy | ≤±1% | ≤±1% | ≤±1% | |
| User Interface & Control | ||||
| Display | 10.1* touch screen | |||
| Screen Material | LCD | |||
| Push Buttons | Operation buttons/Emergency buttons | |||
| User Authentication | RFID.OCPP.QR code,Password,Application | |||
| Support language | English (Other languages available upon request) | |||
| Communication | ||||
| External | Ethernet.WIFI.3G/40 | |||
| Internal | CAN.RS485.RS232 | |||
| Environmental | ||||
| Operating Temperature | -30 C ~ +50 C | |||
| Humidity | <95% relative humidity, non-condensing | |||
| Altitude | s2000m(6000 feet) | |||
| Mechanical | ||||
| Ingress protection | IP55 | |||
| Enclosure Protection | IK10 | |||
| Cooling | Air forced | |||
| Installation Method | Wall-mount / Stand-pile | |||
| Protection | ||||
| Protection | Over current, Under voltage, Over voltage, Residual current, Surge protection. Short circuit, Over temperature, Ground fault | |||
| Regulation | ||||
| Certificate | CE and CB certificated by TUV Rheinland | |||
| Standard | EN IEC-61851-1:2019; EN61851 -23:2014: EN 61851-24:2014; EN IEC 61851-21-2:2021 | |||